Playbook guide and glossary

How the library is organized, what its metadata means, and the field terms used throughout BlueLux guidance.

How the library is organized

Sections group guidance by subject. Types describe what the document helps you do. Tags connect a few tightly related subjects across sections. Risk describes the most serious credible consequence covered by the document. Status remains an editorial control and appears publicly only while an entry is a draft.

Start Here is a curated reading path, not another section. A document can move between sections without changing its ID. Within each section, editors assign an explicit reading order.

Sections

Use a section when you know the part of the work. The seven sections stay broad on purpose, so readers do not have to guess between several overlapping categories.

Pool & Spa Basics

How pools and spas work, how water moves, and the concepts that support sound field decisions.

View 15

Service Visits

The field workflow from arrival and access through inspection, service, and handoff.

View 5

Cleaning

Field procedures for skimming, brushing, vacuuming, baskets, tile, and surfaces.

View 8

Water Chemistry

Testing, interpretation, dosing, water balance, contamination, and common conditions.

View 23

Equipment

Pumps, filters, heaters, valves, automation, salt systems, cleaners, covers, and equipment problems.

View 36

Safety

Chemical, electrical, gas, pressure, heat, contamination, weather, and stop-work guidance.

View 15

Quality & Documentation

What good work looks like, what must be recorded, and how service quality is verified.

View 9

How document IDs and versions work

BLX - SOP - 002 ยท v0.1
BLX
The BlueLux document namespace.
SOP
The stable document-series prefix assigned when this entry was created. It may differ from the current plain-language type label.
002
A stable serial identifier within that type. It is not a reading order or priority rank.
v0.1
The content version. Drafts normally remain below 1.0; published revisions advance under BlueLux version control.

The ID stays stable when a title is refined or a document moves between sections. Links use readable slugs, while the ID is the durable reference for records, training, and future systems.

Document types

BLX-FND / BLX-EQP

Guide

Explains a core concept or equipment family so the reader can understand normal operation, evidence, limitations, and controlling instructions.

View 30
BLX-SOP

Procedure

Gives an ordered, repeatable field task with a quick reference, stop conditions, completion criteria, and documentation when the work creates a record.

View 34
BLX-DIA

Troubleshooting Guide

Starts with a symptom and organizes safe observations, checks, likely causes, and escalation boundaries without granting repair authority.

View 16
BLX-QRF

Field Reference

Provides calculations, conversions, targets, decision bands, or other compact information for quick field use.

View 9
BLX-CHK

Checklist

Provides a concise verification sequence for inspection, closeout, documentation, or another defined checkpoint.

View 3
BLX-STD

Quality Standard

Defines an acceptable outcome, condition, quality level, or decision boundary used to evaluate work.

View 7
BLX-SAF

Safety Guide

Defines hazard recognition, protective controls, stop-work conditions, emergency actions, and qualified referral boundaries.

View 12

Risk levels

Risk is based on the most serious credible consequence covered by the document when a control, boundary, or stop condition is missed. It is not a prediction that harm will occur, a measure of how often the task is performed, or permission to perform the work.

Low risk

The task is normally observational or routine, and a bounded mistake is unlikely to create serious harm or major damage when the stated limits are followed.

View 4

Moderate risk

The work includes controlled operational or service risks. A mistake can damage equipment, impair water care, or create a condition that requires corrective work.

View 16

High risk

A credible mistake can create meaningful chemical, pressure, suction, hydraulic, water-quality, equipment, or property harm. Exact procedures and stop conditions matter.

View 57

Critical risk

The subject includes a credible path to severe injury, poisoning, drowning, fire, electric shock, structural damage, or another major consequence. Strict boundaries and escalation control.

View 34

Publication statuses

Draft

Visible for development and review, but not yet a published BlueLux field standard.

0 visible

In review

Under active source, technical, safety, or field review. Approval requirements are not yet complete.

0 visible

Published

Authorized by BlueLux Operations for use within its stated scope, prerequisites, and limitations. A named peer-review marker appears separately when completed.

111 visible

Retired

No longer current. Use the identified replacement or obtain direction from BlueLux Operations.

0 visible

Scope levels

Scope labels describe the kind of action discussed. They do not override a technician's training, authorization, the equipment manual, law, or the document's stop conditions.

Inspect
Observe, measure, photograph, identify, and record without changing the system.
Operate
Use a normal installed control for its understood and authorized purpose.
Maintain
Perform the defined recurring care task within the applicable procedure and equipment instructions.
Repair
Correct, replace, alter, or restore a component only when the work is separately authorized and qualified.
Refer
Stop at the stated boundary and route the condition to BlueLux Operations or the appropriate qualified professional.

Facility scope

Most Playbook guidance is universal and carries no facility badge. A badge appears only when the entire document is limited to residential work, commercial or public aquatics, or a named jurisdiction. Short differences inside an otherwise universal article appear as callouts beside the affected guidance.

Residential

This document is limited to residential pools or spas.

None yet

Commercial/Public Aquatics

This document is limited to commercial or public aquatic facilities.

View 20

Jurisdiction-specific

This document applies only within the jurisdiction identified in the article.

View 1

Search, sections, and tags

Header search ranks exact IDs and titles first, then keywords, headings, document types, sections, tags, descriptions, risk, and scope. It recognizes common aliases such as CYA and stabilizer, DE and diatomaceous earth, or hot tub and spa, and tolerates a small spelling error in longer terms.

Tags are explicit editorial metadata, limited to three per entry. Use them when the same subject crosses section boundaries, such as filters appearing in equipment guides, procedures, troubleshooting guides, and safety guidance.

Open search and filters

Field terminology

Baseline

A documented normal reading or operating state captured under comparable conditions and used to identify meaningful change.

Find entries

Calcium hardness

The measured concentration of dissolved calcium expressed as calcium carbonate. It is one input to water-balance and saturation decisions.

Find entries

Combined chlorine

Chlorine measured as combined compounds rather than free available chlorine. It is calculated from valid total and free chlorine results.

Find entries

Cyanuric acid (CYA)

A chlorine stabilizer that changes the relationship between measured free chlorine and active sanitizer conditions.

Find entries

Free chlorine

The measured chlorine available in forms that can participate in sanitizing and oxidation, interpreted with pH, CYA, temperature, and system conditions.

Find entries

GPM

Gallons per minute, a water-flow rate. Displayed or estimated GPM is useful only when the measurement method and operating state are known.

Find entries

Hydraulic state

The complete water-path condition at a moment in time, including pump command, speed, valves, suction, returns, features, and dependent equipment.

Find entries

LSI or CSI

Saturation-index models used to estimate calcium-carbonate scaling or dissolving tendency from several measured water conditions.

Find entries

Prime

The condition in which the pump and intended suction path contain enough water for stable circulation without persistent air ingestion.

Find entries

PSI

Pounds per square inch, commonly used for filter pressure. A reading requires a working gauge and a matched equipment state to be meaningful.

Find entries

Sanitizer

The approved active system used to control microorganisms. A sanitizer reading is not, by itself, proof that every water condition is acceptable.

Find entries

Skimmer

A surface-level suction component that draws floating debris toward a basket and the circulation system when water level and flow are suitable.

Find entries

Total alkalinity

A measure of water's acid-neutralizing capacity, expressed as calcium carbonate and interpreted as part of the complete balance system.

Find entries

Water balance

The interacting condition of pH, alkalinity, calcium, temperature, dissolved solids, stabilizer, and other factors affecting comfort, surfaces, and equipment.

Find entries