All case studies

Stabilizer correction field outcome

CYA moved from 30 to 50 ppm while total alkalinity held at 100 ppm

A 2-pound cyanuric-acid treatment moved CYA from 30 to 50 ppm while the paired weekly plan moved pH from 8.0 to 7.6 and held total alkalinity at 100 ppm.

San Diego County, California · August 12 to August 19, 2026 (7 days)

CYA
30 ppm50 ppm
Total alkalinity
100 ppm100 ppm
Free chlorine
4 ppm8 ppm
pH
8.07.6

The situation

  • Low stabilizer and high pH required coordinated correction without moving total alkalinity.

Starting readings

  • CYA: 30 ppm
  • Total alkalinity: 100 ppm
  • Free chlorine: 4 ppm
  • pH: 8.0

Treatment recorded

  • 2 pounds cyanuric acid
  • 1 US gallon of 12.5% liquid chlorine
  • 0.25 US gallons of 31.45% muriatic acid

Follow-up readings

  • CYA: 50 ppm
  • Total alkalinity: 100 ppm
  • Free chlorine: 8 ppm
  • pH: 7.6

Record basis

Anonymized BlueLux field-service record with paired readings, recorded treatment amounts, and visit documentation reviewed in September 2026. Customer identity and street address are excluded.